Austest Sydney and Melbourne have expanded their environmental test capabilities with new Salt Spray and Temperature/Humidity chambers.  This testing is suitable for tropical country climate tests, AS/NZS 4601 and standards such as those relating to Taxi Cab Alarm Systems / passenger transport regulation 2007.

Sydney

  • Combined Temperature -70°C to +150°C  and Humidity 30% – 98% rh Chamber for equipment 1m(w) x 1m(d) x 2m(h)
  •  Tropical Climate test chamber 2.4m(w) x 2.2m(d) x 2.8m(h) ,constant humidity 93%
  • Temperature test chamber 4.8m(w) x 2.3m(d) x 2.8m(h)  -10°C to 50°C
  • Salt Spray Chambers 1m(d) x 2m(w) x .9m(h) continuous or periodic cycling salt mist with temp range 35-55oC to ASTM B117 and AS/IEC/EN 60068.2.52
  • Vibration to IEC/EN61373:2010 and MIL-STD-810 from 1Hz to 3KHz sine, random and shock
  • Water and Dust ingress capabilities to IP 68
  • UV-A and UV Broad spectrum

Melbourne

  • Combined Temperature and Humidity Chamber for equipment  0.9m(w) x 0.7m(d) 1.5m(h),   -30oC to +70oC,  Humidity up to 98%
  • Water and Dust ingress capabilities to IP 68
  • Miscellaneous ovens up to +200oC
  • Vibration to IEC/EN61373:2010 and MIL-STD-810 from 1Hz to 3KHz sine, random and shock
  • UV Broad Spectrum
Salt Spray Chamber
Salt Spray Chamber